Limit of triamcinolone acetonide
Mobile phase
and
Chromatographic systemProceed as directed in the
Assay.
Standard solution
Dissolve an accurately weighed quantity of triamcinolone acetonide in methanol, and dilute quantitatively, and stepwise if necessary, with methanol to obtain a solution having a known concentration of about 0.004 mg per mL.
Test solution
Use the Assay preparation.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the responses for all of the peaks. Calculate the percentage of triamcinolone acetonide in the portion of Triamcinolone Hexacetonide taken by the formula:
100(C / D)(rU / rS),
in which
C is the concentration, in mg per mL, of triamcinolone acetonide in the
Standard solution,
D is the concentration, in mg per mL, of triamcinolone hexacetonide in the
Test solution, and
rU and
rS are the peak responses for triamcinolone acetonide obtained from the
Test solution and the
Standard solution, respectively: not more than 1.0% is found.
Assay
Mobile phase
Prepare a filtered and degassed mixture of methanol and water (75:25). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Triamcinolone Hexacetonide RS in methanol, and dilute quantitatively, and stepwise if necessary, with methanol to obtain a solution having a known concentration of about 0.4 mg per mL.
System suitability solution
Dissolve suitable quantities of triamcinolone acetonide and
USP Triamcinolone Hexacetonide RS in methanol to obtain a solution containing about 0.4 mg per mL of each.
Assay preparation
Transfer about 40 mg of Triamcinolone Hexacetonide, accurately weighed, to a 100-mL volumetric flask. Dissolve in and dilute with methanol to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector and a 4.6-mm × 25-cm column that contains packing L1. The flow rate is about 2 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.27 for triamcinolone acetonide and 1.0 for triamcinolone hexacetonide, the resolution,
R, between triamcinolone acetonide and triamcinolone hexacetonide is not less than 7.5, the tailing factor for triamcinolone hexacetonide is not more than 1.3, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
30H
41FO
7 in the portion of Triamcinolone Hexacetonide taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Triamcinolone Hexacetonide RS in the
Standard preparation, and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.